Must power limited
|
Price: | 100.0~405.0 USD |
Payment Terms: | T/T |
Place of Origin: | , China (Mainland) |
Add to My Favorites | |
HiSupplier Escrow |
MODEL | 115V Models | 230V Models | |
OUTPUT | |||
Power Levels crated at | 12KW;15KW;20KW | 12KW;15KW;20KW | |
Output Voltage | 100V/110V/115V/120V Selectable | 220v±3% | |
Voltage Waveform | Pure Sine wave | ||
Crest Factor | 3:1 | ||
Output Frequency | Auto Select for 50/60Hz | ||
(Synchronized to Mains) | 47Hz ~ 55Hz for 50Hz nominal 56Hz ~ 65Hz for 60Hz nominal | ||
Regulation (Nominal) | ±10% typical of nominal voltage | ||
Regulation | ±3% of selected output voltage | ||
(Battery mode) | remote set-up software | ||
Transfer time | Blackout 3ms typical Brownout 1ms typical Battery mode to Normal mode??1ms typical | ||
Over current protection | Over load alarm level 100% ~ 120% Over load shutdown level 120% ~ 190% (Adjustable by using the remote set-up software) | ||
INPUT | |||
Nominal Voltage | 100V/110V/115V/120V Selectable | 200V/220V/230V/240V Selectable | |
Input Frequency | 47Hz ~ 65Hz, 50/60Hz auto-sensing | ||
Efficiency (Normal mode) | 97% | ||
Noise Filtering | Full time EMI/RFI filtering | ||
Voltage Range | 75V ~ 155V | 175V-265V | |
BATTERY | |||
Battery type | Lead-Acid 50Ah to 500Ah (Recommended) | Lead-Acid 50Ah to 500Ah (Recommended) | |
Voltage | 10KW: 96Vdc | 10KW: 96Vdc | |
12KW/15KW:192Vdc | 12KW/15KW:192Vdc | ||
Typical backup time | No Limit | ||
Charging method | Quick charging when battery is not fully charged, trickle charging when battery is 90% fully charged. | ||
Maximum charging current | 15A | 15A | |
Average charging | Quick charging mode:14V maximum. | ||
voltage for each battery | Trickle charging mode:13.5V (adjustable with the remote set-up software) | ||
Protection | Over current protection & Over charging voltage protection (SCR control) Thermal protection (CPU control) When temperature inside the unit is over 45 °C, charger will stop charging for 2 minutes followed by an 2 minutes charging. The cycle will be repeate | ||
Monitoring | Smart monitoring & warning for failed battery or open-circuit battery. Auto-detection each time when power on or every 6 days. | ||
COMMUNICATIONS & MANAGEMENT | |||
Standard Interface port | UPSilon2000 compatible; optional for RS232 . | ||
Control panel | LCD or LED Selectable | ||
Audible alarm | Alarm on battery:Low battery & Battery over voltage Alarm on abnormal operation:Over load, Short-circuit, & Over heat | ||
Green mode function | 1% to 14% of full load (adjustable by using the remote set-up software) | ||
(Auto-shut-off in blackout) | The default setting is OFF. | ||
Cooling fan control | Auto on / off, controlled by temperature & operation mode | ||
ENVIRONMENTAL AND SAFETY | |||
Operating Temperature | Up to 1500 meters:0°Cto 40°C | ||
Transit/storage Temp. | 15°C below zero to 55°C | ||
Relative Humidity | 5 - 95% non condensing | ||
Operating Altitude | 0 ~ 3000 meters | ||
PHYSICAL | |||
Appearance | product size(mm) | 555*360*720 | |
Net Weight(Kg) | 10KW: 56.5, 15KW: 78.5; 20KW: 108.50 | ||
Carton Gross Weight | 10KW: 60.7, 15KW: 82.8; 20KW: 112.80 | ||
shipping size | 720*450*865 |